Business & Industrial Testing

Commercial EICR & Electrical Testing
in Brechin

Keep your business compliant with regular commercial electrical inspections. We test shops, offices, farms, and industrial units across Angus.

Fully Insured NICEIC Certified Local to DD9
Commercial EICR Testing Brechin Angus
OUT-OF-HOURS

CommercialEICR Testing for Angus Businesses

We test retail units, workshops, offices, and agricultural buildings. Out-of-hours testing available to avoid disrupting trade.

Most Popular
Retail EICR Brechin

Retail / Office EICR

For shops, cafes, and small offices. We test distribution boards, lighting circuits, socket outlets, and emergency lighting. Includes fire alarm power supply testing.

  • Full Circuit Testing
  • Emergency Lighting Check
  • Insurance-Compliant Report
Heavy Machinery
Industrial EICR Testing

Industrial / Workshop EICR

For factories, garages, and workshops. We test three-phase supplies, machine isolators, hoists, compressors, and high-load equipment. Out-of-hours testing available.

  • Three-Phase Testing
  • Machinery Isolators
  • HSE Compliance
Farm Specialists
Agricultural EICR Testing

Agricultural Building EICR

For farms, milking parlours, and grain stores. We test outdoor supplies, submain cables, livestock equipment, and feed systems. Angus farm specialists.

  • Outdoor/SWA Cables
  • Livestock Equipment
  • Rural Earthing Systems

PAT Testing & Emergency Lighting Available

We also provide Portable Appliance Testing (PAT) and Emergency Lighting Certification. Bundle both with your EICR for a fixed-price compliance package.

James Leslie - Brechin Electrician
James Leslie
Founder & Lead Engineer

Ex-RAF. Ex-Fire Service.
100% Brechin Local.

I served as a Retained Firefighter with Brechin Fire Service and a Royal Air Force Electrical Engineer. I have tested electrical systems in military workshops, hangars, and industrial facilities.

That's why Angus businesses trust me with their commercial testing. I understand three-phase supplies, industrial machinery, and agricultural equipment. I know what HSE inspectors look for, and I ensure your business stays compliant and safe.

RAF
Royal Air Force
Engineer
FIRE
Brechin
Fire Service
30Y
30 Years
Experience

Why Businesses Need Regular EICRs

Commercial electrical systems work harder than domestic ones. Regular testing prevents downtime, fires, and liability claims.

Test Every
3-5 Years

Commercial properties require testing every 3-5 years (vs 5-10 years domestic). High-load equipment degrades faster.

Insurance
Required

Most commercial insurance policies demand a current EICR. No certificate = invalid claim if electrical fire damages stock.

HSE
Compliance

Health & Safety Executive requires businesses to maintain safe electrical systems. Prosecutions can result in unlimited fines.

Prevent
Downtime

An unexpected electrical failure can shut your business for days. Regular testing catches faults early before they cause costly downtime.

What Insurers Require

Commercial insurance policies have strict electrical testing requirements.

EICR Every 3-5 Years

Most policies require proof of testing every 3-5 years. Some high-risk industries (manufacturing, food) require annual testing.

PAT Testing Annually

Portable appliances (computers, kettles, tools) must be PAT tested yearly. We provide combined EICR + PAT packages.

Emergency Lighting Every 6 Months

If you have emergency lighting, it must be tested every 6 months and annually certified. We test duration, brightness, and battery backup.

Liability Risks

If faulty electrics injure a customer, employee, or contractor and you can't prove regular testing, you're personally liable. HSE can prosecute directors.

CommonCommercial Properties We Test in Angus

From high street shops to industrial workshops, we cover all business types.

Retail Shop EICR
High Street

Shops & Cafes

We test retail units, cafes, and restaurants. Includes tills, display lighting, kitchen equipment, and fire alarm supplies. Out-of-hours available.

Office EICR Testing

Offices

Full office testing including server rooms, data comms, UPS systems, and underfloor power. We schedule around your working hours.

Workshop EICR Testing

Garages & Workshops

We test three-phase supplies, vehicle lifts, compressors, welders, and extraction systems. Common in Angus agricultural engineering firms.

Farm EICR Testing

Farms & Barns

Milking parlours, grain dryers, livestock feeders, and outdoor SWA cable runs. We know TN-C-S earthing issues in rural Angus.

We Cover These Angus Zones

PostcodeTown / AreaArrival Time
DD9 6BRECHIN / EDZELL< 24 HOURS
DD9 7TARFSIDE / GLEN ESKNEXT DAY
DD10 8MONTROSE / HILLSIDENEXT DAY
DD8 1FORFAR / LETHAMNEXT DAY
AB30LAURENCEKIRK48 HOURS

Faulty Electrics in Commercial Settings = Liability Nightmare

You're responsible for the safety of employees, customers, and contractors. If someone is injured by faulty electrics and you can't prove regular testing, you face prosecution under the Health & Safety at Work Act 1974.

Directors can be personally prosecuted and face unlimited fines or imprisonment. Don't risk it. Our commercial EICRs provide the legal proof you need.

OurCommercial EICR Testing Process

Minimal disruption to your business. Out-of-hours testing available.

Site Survey
01

Site Survey

We visit your premises to assess the electrical installation. We identify all distribution boards, sub-mains, machinery, and high-load equipment. Fixed quote provided.

Schedule Testing
02

Schedule Testing

We book testing at a time that suits you. Out-of-hours testing (evenings/weekends) available for businesses that can't afford downtime. Power interruptions kept to minimum.

Comprehensive Testing
03

Comprehensive Testing

We test all circuits, earthing, RCD protection, and three-phase supplies. We inspect switchgear, check emergency lighting, and test machinery isolators. Photos taken of any defects.

Report & Certificate
04

Report & Certificate

You receive a detailed EICR with observations, recommendations, and test results. If remedials are needed, we quote and can fix them immediately. Certificate valid 3-5 years.

Commercial EICR Testing FAQs

? How often do commercial properties need testing?

Most commercial properties require EICR testing every 3-5 years. High-risk environments (factories, workshops with heavy machinery) may need annual testing. Check your insurance policy.

? Can you test out of hours?

Yes. We offer evening and weekend testing for businesses that can't afford downtime. Popular with shops, restaurants, and 24/7 operations. No extra charge for out-of-hours work.

? Do you test emergency lighting?

Yes. We test emergency lighting as part of the EICR or as a standalone service. We check battery duration (3 hours minimum), brightness levels, and self-test functionality.

? What about PAT testing?

PAT (Portable Appliance Testing) is separate but we offer it as a bundle. We test computers, kettles, power tools, extension leads, and all portable equipment. Required annually by most insurers.

? How much does commercial testing cost?

Small shops/offices start from £250-£400. Larger industrial units depend on the number of circuits and machinery. We provide fixed quotes after a free site survey.

? Will you turn off my power?

Briefly, yes. We need to isolate circuits to test them safely. We work section-by-section to minimize disruption. Critical systems (servers, fridges) can often stay on.

? What if we fail the test?

We categorize faults (C1, C2, C3). Dangerous faults (C1) must be fixed immediately—we can isolate circuits to keep you safe. We quote for remedials and can fix them on a return visit.

? Do you test three-phase supplies?

Yes. We're experienced with three-phase systems common in workshops, farms, and industrial units. We test phase balance, neutral currents, and machinery isolators.

? Can you test farms and agricultural buildings?

Absolutely. We're familiar with Angus farm electrics—milking parlours, grain stores, livestock equipment, and outdoor SWA cable runs. We know TN-C-S earthing issues in rural areas.

? Do you provide digital certificates?

Yes. We email PDF reports the same day. Hard copies available if needed for HSE inspections or insurance audits.

? What's the penalty for not having an EICR?

HSE can prosecute under the Electricity at Work Regulations 1989. Fines are unlimited. Directors can be personally prosecuted if negligence causes injury or death.

? Do you work with insurance assessors?

Yes. If you've had a fire or electrical fault, we can provide independent reports for insurance claims. We work with loss adjusters and provide expert witness statements if needed.

Keep Your Business Safe & Compliant

Expert commercial testing for Angus businesses.
Out-of-hours available. Fixed prices. Fast turnaround.

01356 235858